Offering the highest throughput of our entire DVS range, the DVS Endeavour precisely controls and measures temperature and relative humidity while simultaneously recording the highest resolution changes in mass on up to 5 samples simultaneously.
Combined with a range of modular accessories, the DVS Endeavour is one of the most versatile DVS instruments on the market.
Temperature |
Temperature controlled enclosure Control range: 10°C to 70oC Control precision: ± 0.1oC Enclosure provides anti-condensation protection. |
|
---|---|---|
High-temperature pre-heater for sample drying/activation | Delivers local sample temperatures of up to 200 °C Heating ramp rates: up to 5 °C / min Sensors: Pt-100 thermocouple |
|
Mass Measurement |
Ultrabalance Low Mass | Maximum load: 1000 mg Mass change: ±150 mg Resolution: 0.01 μg Balance noise: ≤ 0.3 μg |
Ultrabalance High Mass | Maximum load: 5000 mg Mass change: ±1000 mg Resolution: 0.1 μg Balance noise: ≤ 3 μg |
|
Endeavour Stand |
Manifold: 316 stainless steel Seals: Viton Tubing: 1/4 inch stainless steel |
|
Water Reservoir |
Material: glass 5 L as standard |
|
Organic Vapor Generation and Measurement with Speed of Sound Sensor |
High-accuracy digital mass flow controllers for vapor and gas delivery | |
Speed of Sound Sensor for organic vapors |
• Carrier Gas – Dry air or Nitrogen • Partial Pressure range from 0 to 90% • Partial Pressure accuracy from 10 – 70 °C ±1% • In-line real-time Speed-of-Sound Sensor for organic vapor Partial Pressure (P/Po) measurements and control with a typical resolution of ±0.1% P/Po • Automated zeroing of Speed of Sound sensor prior to each experiment • Note: SMS limits the use of organic solvents to 20°C below their boiling points. • Relative Humidity Sensor, Generation, & Measurement |
|
Sensor |
• Capacitance probe • Carrier Gas – Dry air or Nitrogen • Water vapor generation range and accuracy: • 11-σ confidence level with %RH or P/Po calibration performance based on SMS factory certified methods (Salts Calibrations or equivalent method) • In-line real-time Humidity Probe for Relative Humidity measurements and control with a resolution of 0.1% RH |
|
System Software |
Next-generation purpose-built control and evaluation software for the most advanced experimental design and data analysis. | |
Generation & Measurement |
High-accuracy digital mass flow controllers and capacitance probe |
Complex protocols for multiple experimental sequences using sample pre-heating and conditioning; isotherm, isobar and ramped humidity and organic vapor methods; single or dual vapor delivery, and control; fixed time or mass derivative steps.
• Sample pre-heating • Vapor sorption • Vapor exchange • Dual vapor co-adsorption • Temperature changes in a single experiment, including Ramp or step changes in relative humidity • Automated video image acquisition • Organic vapor sorption partial pressure • Temperature stages may be based on fixed-time or user-defined dm/dt criteria • Complex isotherm experiments • Experiments may include half, full or multiple partial pressure or temperature cycles |
||
Analysis |
• Isotherms • Permeability and diffusion • Kinetics information • Heat of sorption • Tg determinations • Amorphous content • BET |
|
21CFR Part 11 software solution is available for all DVS software upon request. |
Acetone | Chloroform | Cyclohexane | Decane | Dichloromethane | Ethanol |
Ethyl acetate | Ethyl benzene | Heptane | Hexane | Isopropanol | Methanol |
Nonane | Octane | Toluene | Water | M-Xylene | p-Xylene |