BSC from Biobase provides three protections: operator, sample, and environment. Airflow system: 60% air recirculation, 30% air exhaust A2 cabinet is suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
This cabinet defined as class II A2 type microbiological safety cabinet.
Three protection: operator, sample and environment. Airflow system: 70% air recirculation, 30% air exhaust A2 Cabinet is suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
Advantages:
Technical Specifications
Model | BSC-4FA2(4') | BSC-3FA2-GL(3') BSC-3FA2-NA(3') |
BSC-4FA2-GL(4') BSC-4FA2-NA(4') |
BSC-6FA2-GL(6') BSC-6FA2-NA(6') |
|
---|---|---|---|---|---|
External Size (W*D*H)mm |
1383*775*2295 | 1087*775*2265 | 1383*775*2295 | 1873*775*2295 | |
Internal Size (W*D*H)mm |
1210*600*660 | 910*600*660 | 1210*600*660 | 1700*600*660 | |
Work Surface Height |
750mm | 750mm | 750mm | 750mm | |
Max Opening | 550mm (22’’) | 520mm(20.5’’) | 550mm (22’’) | 550mm (22’’) | |
Tested Opening | Safety height 200mm (8'') | Safety height 254mm (10’’) | Safety height 254mm (10’’) | Safety height 254mm (10’’) | |
Airflow Volume (Inflow) | 462m3/h(272cfm) | 441m3/h(259cfm) | 587m3/h(346cfm) | 824m3/h(485cfm) | |
Airflow Volume (Down flow) | 65%:863m3/h(507cfm) | 60%:649m3/h(382cfm) | 60%:863m3/h(507cfm) | 60%:1212m3/h(713cfm) | |
Airflow Volume (Exhaust) | 35%:462m3/h(272cfm) | 40%:445m3/h(259cfm) | 40%:587m3/h(346cfm) | 40%:824m3/h(485cfm) | |
Front Window | Motorized. Two-layer laminated toughened glass ≥5mm. Anti UV |
Motorized. Two-layer laminated toughened glass ≥5mm. Anti UV |
Motorized. Two-layer laminated toughened glass ≥5mm. Anti UV |
Motorized. Two-layer laminated toughened glass ≥5mm. Anti UV |
|
Illumination | ≥1000Lux | ≥1000Lux | ≥1000Lux | ≥1000Lux | |
Waterproof Socket | 2, Total consumption:≤500W | 2, Total consumption:≤500W | 2, Total consumption:≤500W | 2, Total consumption:≤500W | |
Power Supply | AC220V±10%, 50/60Hz; 110V±10%,60Hz, Full load Amps: 9A, BTU/Hr: 1689 |
AC220V±10%, 50/60Hz; 110V±10%,60Hz, Full load Amps: 9A, BTU/Hr: 1689 |
AC220V±10%, 50/60Hz; 110V±10%,60Hz, Full load Amps: 9A, BTU/Hr: 1689 |
AC220V±10%, 50/60Hz; 110V±10%,60Hz, Full load Amps: 9A, BTU/Hr: 1689 |
|
Consumption | 400W | 300W | 400W | 500W | |
Illuminating Lamp | 18W*2 | 10W*2 | 18W*2 | 22W*2 | |
Package Size (W*D*H)mm |
1540*1080*1900 | 1250*1080*1840 | 1540*1080*1900 | 2020*1080*1900 | |
This product belong to Class II B2 Biosafety Cabinet(BSC) which fully meets the requirements of US Standard ANSI/NSF49:2016. BSC is a kind of negative pressure filtration system for protecting operator, laboratory environment and experiment materials.
BSC is a kind of necessary equipment in laboratories of microbiology, biomedical science, genetic recombination, animal experiment and biological products. It plays a significant role in the occasion where protective actions are needed for operator, such as healthcare, pharmaceutical analysis, and biomedical research. This equipment provides a germ-free and dust-free working environment during bacterial culture.
Advantages:
Technical Specifications
Model | BSC-4FB2-NA | BSC-4FB2-GL | |
---|---|---|---|
External Size(W*D*H) | 1383×775×2325mm | 1383×775×2325mm | |
Internal Size(W*D*H) | 1210×600×660 mm | 1210×600×660 mm | |
Tested Opening | Safety height 200mm (8'') | Safety height 200mm (8'') | |
Max Opening | 550mm(22’’) | 550mm(22’’) | |
Exhaust Airflow Volume | 100%:1320m3/h(776cfm) | 100%:1320m3/h(776cfm) | |
Front Window | Motorized. Two-layer laminated toughened glass ≥5mm. Anti UV |
Motorized. Two-layer laminated toughened glass ≥5mm. Anti UV |
|
Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz, Full load Amps: 9A, BTU/Hr: 1689 |
AC220V±10%, 50/60Hz; 110V±10%, 60Hz, Full load Amps: 9A, BTU/Hr: 1689 |
|
Tap | Water tap*1, Gas tap *1 | Water tap*1, Gas tap *1 | |
Ground Resistance | ≤ 0.10Ω | ≤ 0.10Ω | |
DC Motor | One ECM motor, 110V& 220V acceptable, Speed adjustable, high efficiency and low power consumption |
One ECM motor, 110V& 220V acceptable, Speed adjustable, high efficiency and low power consumption |
|
Standard Accessory | Illuminating lamp, UV lamp *2, Base stand, SS water & gas taps, Drain valve, Waterproof sockets, Stainless Steel I.V. Bar with 10 hooks |
Illuminating lamp, UV lamp *2, Base stand, SS water & gas taps, Drain valve, Waterproof sockets, Stainless Steel I.V. Bar with 10 hooks |
|
Package Size (W*D*H) | 1540*1080*1950mm | 1540*1080*1950mm | |
Gross Weight | 350Kg | 350Kg | |
Class III Biosafety Cabinet is totally enclosed and gas tight with ULPA filtered supply and exhaust air. Work is performed with long-sleeved gloves. The cabinet is kept under negative pressure of at least 120Pa, and airflow is maintained by a dedicated exterior exhaust system. It can protect the operator, product, and environment.
Advantages:
Accessories:
Technical Specifications
Model | BSC-1100IIIX | BSC-1500IIIX | |
---|---|---|---|
External Size(W*D*H) | 1540*880*2000 mm | 1790*880*2080 mm | |
Internal Size(W*D*H) | 910*650*660 mm | 1165*650*660 mm | |
Front Window | 8 mm toughened glass, anti-ultraviolet radiation | 8 mm toughened glass, anti-ultraviolet radiation | |
Display | LCD display | LCD display | |
Pressure | ≥ negative120 Pa | ≥ negative120 Pa | |
Air supply filter | Efficiency 99.9995% at 0.12μm | Efficiency 99.9995% at 0.12μm | |
First exhaust filter | Efficiency 99.9995% at 0.12μm | Efficiency 99.9995% at 0.12μm | |
Second exhaust filter | Efficiency 99.9995% at 0.12μm | Efficiency 99.9995% at 0.12μm | |
Noise | ≤67dB | ≤67dB | |
Work Zone Material | 304 stainless steel | 304 stainless steel | |
Consumption | 1200W | 1300W | |
LED Lamp | 12W*2 | 16W*2 | |
Power Supply | AC220V±10% ,50/60 Hz; 110V±10%,60Hz |
AC220V±10% ,50/60 Hz; 110V±10%,60Hz |
|
Gross Weight | 350kg | 450kg | |
Package Size(W*D*H) | 1635*1065*2160mm | 1890*1065*2240mm | |
Standard Accessories | Gloves, fluorescent lamp, UV lamp*3, remote control, pressure meter, drain valve |