Vapor Sorption Analysis
TA Instruments offers the most sensitive, versatile and productive moisture sorption analyzers on the market.
Vapor Sorption Analysis is a technique in which a sample is subjected to varying conditions of humidity and temperature, and the response of the sample is measured gravimetrically. Understanding the effects of water content on structure and properties is critical in the development, processing and end use of a broad spectrum of materials. TA Instruments offers the most sensitive, versatile, and productive moisture sorption analyzers on the market. The Discovery SA combines a high-sensitivity thermobalance, innovative humidity control chamber, and reliable autosampler. Innovative technology combined with our unparalleled reputation for service and support make TA Instruments the clear choice of scientists worldwide for vapor sorption studies.
Isosorp SA
Magnetic Suspension Balance (MSB) |
Pressure [1] | Temperature | Dosing System Type | ||||
---|---|---|---|---|---|---|---|
IsoSORP SA Model | Resolution (μg) |
Mass Range (g) | Max. Pressure (bar) | Min (°C) | Max (°C) | ||
400-150, S-G | 10 | 25 | 150 | RT | 400°C | Static Gas (S-G) | |
400-150, S-G XR | 1 | 10 | 150 | RT | 400°C | Static Gas (S-G) | |
400-150, S-G Cryo | 10 | 25 | 150 | 196°C [2] | 400°C | Static Gas (S-G) | |
400-150, S-G LT | 10 | 25 | 150 | 20 | 400°C | Static Gas (S-G) | |
400-150. S-G XR LT | 1 | 10 | 150 | -20 | 400°C | Static Gas (S-G) | |
400-50. S-G+V | 10 | 25 | 50 | RI | 400°C | Static Gas & Vapor (S-G+V) | |
400-50. S-G+V XR | 1 | 10 | 50 | RT | 400°C | Static Gas & Vapor (S-G+V) | |
400-150, S-SC | 10 | 25 | 150 | RT | 400°C | Static Sub-Critical Fuids and Gas (S-SC) | |
400-150, S-SCLT | 10 | 25 | 150 | -20 | 400°C | Static Sub-Critical Fuids and Gas (S-SC) | |
150-150, S-SC Visi | 10 | 25 | 150 | FT | 150°C | Static Sub-Critical Fuids and Gas (S-SC) | |
150-350. S-SC | 10 | 25 | 350 | RT | 150°C | Static Sub-Critical Fuids and Gas (S-SC) | |
150-350, S-SC LT | 10 | 25 | 350 | -20 | 150°C | Static Sub-Critical Fuids and Gas (S-SC) | |
150-350, S-SC Visi | 10 | 25 | 350 | RT | 150°C | Static Sub-Critical Fuids and Gas (S-SC) | |
150-700, S-SC | 10 | 25 | 700 | RT | 150°C | Static Sub-Critical Fuids and Gas (S-SC) | |
400-50. F.G | 10 | 25 | 50 | RT | 400°C | Flow Gas (F-G) | |
400-50. F.G XR | 1 | 10 | 50 | RT | 400°С | Flow Gas (F-G) | |
400-150. F-G | 10 | 25 | 150 | RT | 400°C | Flow Gas (F-G) | |
400-150. F-G XR | 1 | 10 | 150 | RT | 400°C | Flow Gas (F-G) | |
400-50. F-G+V | 10 | 25 | 50 | RT | 400°C | Flow Gas & Vapor (F-G+V) | |
400-50, F-G+V XR | 1 | 10 | 50 | RT | 400°С | Flow Gas & Vapor (F-G+V) | |
400-150. F.G+V | 10 | 25 | 150 | RI | 400°C | Flow Gas & Vapor (F-G+V) | |
[1] Vacuum specification: 0.0075 Torr possible (requires adequate vacuum pump) [2] Sample can be cooled to -196°C or -186°C, continuous temperature controlling range -150°C to 400°C |
Discovery SA
Dynamic Weighing Range | – | 1000 mg |
---|---|---|
Weighing Resolution | – | 0.01 μg |
Baseline Drift (Standard Deviation) | 24 h Isothermal 25° C and 20% RH | <±0.25 μg |
RH-Ramp 5 %– 85% RH at 25° C | <±1 μg | RH-Ramp 5 %– 85% RH at 25° C |
T-Ramp 25° C to 85° C at 20% RH | <±1 μg | T-Ramp 25° C to 85° C at 20% RH |
Sample Temperature | – | 5° C to 85 °C |
Humidity Control Range | – | 0% to 98% RH |
Humidity Accuracy | – | ±1% RH |
Water Refill Pump | – | Standard Feature |
Autosampler | 10 position 25 position |
Standard Feature Optional, with platinum or sealed aluminum pans |
Sample Pans | Quartz or Metal-coated Quartz 180 μl Platinum 100 μl Aluminum Sealed 20 μl |
Quartz or Metal-coated Quartz 180 μl Platinum 100 μl Aluminum Sealed 20 μl |
TA Instruments invites you to experience the world’s most productive Dynamic Vapor Sorption (DVS) Analyzer, the Discovery SA. Discover the advanced engineering and attention to detail that provides enhancements in every aspect of DVS technology and a new level of user experience. With industry-leading performance, exceptionally wide humidity control range and ease of use, the Discovery SA meets your needs and exceeds your expectations.
Features:
Accuracy for Best Sorption Data
A symmetric microbalance and advanced humidity chamber design deliver industry-leading stable baselines and weighing resolution. The SA provides accurate data for sorption analysis on small material quantities and/or on hydrophobic samples.
Productivity & Reliability
Autosampler and humidifier autofill pump allow for programming experimental queues of up to 10 or 25 samples. Even at high humidity and temperature or long lasting measurements, 24/7 productivity and absolute reliability are provided without user interaction.
Ease of use & Compliance
The App-style touchscreen and 21 CFR Part 11 compliant TRIOS software provide a unique user experience throughout the complete workflow from instrument control, method setup, and experiment to data evaluation.
The IsoSORP SA is an advanced gravimetric instrument featuring a patented* Magnetic Suspension Balance that enables sorption measurements under high pressure or vacuum environments.
Samples can be measured in the presence of a variety of gases or vapors over a wide temperature range covering -196°C to 400°C. A flexible selection of dosing and blending devices provide accurate control of the composition and pressure of the reaction atmosphere. Designed and built with over 20 years of experience and field-proven by hundreds of customers, the Rubotherm Series IsoSORP SA offers the widest available pressure range of all gravimetric sorption analyzers, and represents the industry standard for application-relevant analysis.
* German Patent no. 10 2009 009 204.8
Features and Benefits: